JBJ SP5 50-55 KVA

50 Hz - 1500 rpmVoltage: 380 / 220 V
Motor modelIveco
Cooling systemsRadiator
PRP generator power (kVA)/KWe50/40
STP generator power (kVA)/KWe55/44
Cos Phi power factor0.8
Number of cylinders4 in line
Speed (R.P.M.)1500
Fuel consumption (l/h)At 100%: 11.9 l/h
At 75%: 9.5 l/h
Open generator fuel tank100 l
Soundproofed generator fuel tank150 l
Max. exhaust gas temperature 100% (ºC)541
Exhaust gas flow 100% (m3/min)698
Max. acceptable backpressure (Kpa)5
Air required for combustion 100% (m3/h)675
Alternator fan air flow (m3/m)11.8
Motor fan air flow (m3/s)1.6
Open generator weight950 Kg
Soundproofed generator weight1425 Kg

Open

  • H: 1450 mm
  • L: 2150 mm
  • W: 700 mm

Closed

  • H: 1800 mm
  • L: 2600 mm
  • W: 1100 mm

JBJ SP5 100-110 KVA

50 Hz - 1500 rpmVoltage: 380 / 220 V
Motor modelIveco
Cooling systemsRadiator
PRP generator power (kVA)/KWe100/80
STP generator power (kVA)/KWe110/55
Cos Phi power factor0.8
Number of cylinders4 in line
Speed (R.P.M.)1500
Fuel consumption (l/h)At 100%: 22 l/h
At 75%: 16.2 l/h
Open generator fuel tank100 l
Soundproofed generator fuel tank200 l
Max. exhaust gas temperature 100% (ºC)535
Exhaust gas flow 100% (m3/min)443
Max. acceptable backpressure (Kpa)5
Air required for combustion 100% (m3/h)617
Alternator fan air flow (m3/m)19.3
Motor fan air flow (m3/s)2.2
Open generator weight1250 Kg
Soundproofed generator weight1950 Kg

Open

  • H: 1600 mm

  • L: 2350 mm

  • W: 750 mm

Closed

  • H: 1800 mm
  • L: 2900 mm
  • W: 1100 mm

JBJ MP5 125-138 KVA

50 Hz - 1500 rpmVoltage: 380 / 220 V
Motor modelIveco
Cooling systemsRadiator
PRP generator power (kVA)/KWe125/100
STP generator power (kVA)/KWe138/110.4
Cos Phi power factor0.8
Number of cylinders6 in line
Speed (R.P.M.)1500
Fuel consumption (l/h)At 100%: 28.8 l/h
At 75%: 23.2 l/h
Open generator fuel tank200 l
Soundproofed generator fuel tank350 l
Max. exhaust gas temperature 100% (ºC)528
Exhaust gas flow 100% (m3/min)498
Max. acceptable backpressure (Kpa)5
Air required for combustion 100% (m3/h)475
Alternator fan air flow (m3/m)19.3
Motor fan air flow (m3/s)3.2
Open generator weight1425 Kg
Soundproofed generator weight2275 Kg

Open

  • H: 1650 mm
  • L: 2800 mm
  • W: 800 mm

Closed

  • H: 1950 mm
  • L: 3400 mm
  • W: 1350 mm

JBJ MP5 170-185 KVA

50 Hz - 1500 rpmVoltage: 380 / 220 V
Motor modelIveco
Cooling systemsRadiator
PRP generator power (kVA)/KWe170/136
STP generator power (kVA)/KWe185/148
Cos Phi power factor0.8
Number of cylinders6 in line
Speed (R.P.M.)1500
Fuel consumption (l/h)At 100%: 34.9 l/h
At 75%: 26.2 l/h
Open generator fuel tank200 l
Soundproofed generator fuel tank350 l
Max. exhaust gas temperature 100% (ºC)570
Exhaust gas flow 100% (m3/min)1763.9
Max. acceptable backpressure (Kpa)5
Air required for combustion 100% (m3/h)586
Alternator fan air flow (m3/m)32
Motor fan air flow (m3/s)3.8
Open generator weight1500 Kg
Soundproofed generator weight2350 Kg

Open

  • H: 1700 mm
  • L: 2800 mm
  • W: 800 mm

Closed

  • H: 1950 mm
  • L: 3400 mm
  • W: 1350 mm

JBJ MP5 200-220 KVA

50 Hz - 1500 rpmVoltage: 380 / 220 V
Motor modelIveco
Cooling systemsRadiator
PRP generator power (kVA)/KWe200/160
STP generator power (kVA)/KWe220/176
Cos Phi power factor0.8
Number of cylinders6 in line
Speed (R.P.M.)1500
Fuel consumption (l/h)At 100%: 44 l/h
At 75%: 35.7 l/h
Open generator fuel tank200 l
Soundproofed generator fuel tank350 l
Max. exhaust gas temperature 100% (ºC)550
Exhaust gas flow 100% (m3/min)786
Max. acceptable backpressure (Kpa)6
Air required for combustion 100% (m3/h)754
Alternator fan air flow (m3/m)32
Motor fan air flow (m3/s)3.8
Open generator weight1750 Kg
Soundproofed generator weight2650 Kg

Open

  • H: 1700 mm
  • L: 2750 mm
  • W: 800 mm

Closed

  • H: 2150 mm
  • L: 3800 mm
  • W: 1350 mm

JBJ MP5 300-330 KVA

50 Hz - 1500 rpmVoltage: 380 / 220 V
Motor modelDoosan
Cooling systemsRadiator
PRP generator power (kVA)/KWe300/240
STP generator power (kVA)/KWe330/264
Cos Phi power factor0.8
Number of cylinders6 in line
Speed (R.P.M.)1500
Fuel consumption (l/h)At 100%: 63 l/h
At 75%: 47 l/h
Open generator fuel tank300 l
Soundproofed generator fuel tank350 l
Max. exhaust gas temperature 100% (ºC)590
Exhaust gas flow 100% (m3/min)1442
Max. acceptable backpressure (Kpa)6
Air required for combustion 100% (m3/h)1298
Alternator fan air flow (m3/m)32
Motor fan air flow (m3/s)5.67
Open generator weight2560 Kg
Soundproofed generator weight3510 Kg

Open

  • H: 1700 mm
  • L: 3300 mm
  • W: 1150 mm

Closed

  • H: 2200 mm
  • L: 4500 mm
  • W: 1700 mm

JBJ MP5 350-385 KVA

50 Hz - 1500 rpmVoltage: 380 / 220 V
Motor modelIveco
Cooling systemsRadiator
PRP generator power (kVA)/KWe350/280
STP generator power (kVA)/KWe385/308
Cos Phi power factor0.8
Number of cylinders6 in line
Speed (R.P.M.)1500
Fuel consumption (l/h)At 100%: 70 l/h
At 75%: 57.3 l/h
Open generator fuel tank300 l
Soundproofed generator fuel tank350 l
Max. exhaust gas temperature 100% (ºC)479
Exhaust gas flow 100% (m3/min)1549
Max. acceptable backpressure (Kpa)5
Air required for combustion 100% (m3/h)1.495
Alternator fan air flow (m3/m)32
Motor fan air flow (m3/s)6.8
Open generator weight3100 Kg
Soundproofed generator weight4300 Kg

Open

  • H: 1750 mm
  • L: 3450 mm
  • W: 1300 mm

Closed

  • H: 2200 mm
  • L: 4500 mm
  • W: 1700 mm

JBJ MP5 400-440 KVA

50 Hz - 1500 rpmVoltage: 380 / 220 V
Motor modelIveco
Cooling systemsRadiator
PRP generator power (kVA)/KWe400/320
STP generator power (kVA)/KWe440/352
Cos Phi power factor0.8
Number of cylinders6 in line
Speed (R.P.M.)1500
Fuel consumption (l/h)At 100%: 87.5 l/h
At 75%: 72.5 l/h
Open generator fuel tank300 l
Soundproofed generator fuel tank350 l
Max. exhaust gas temperature 100% (ºC)445
Exhaust gas flow 100% (m3/min)1836
Max. acceptable backpressure (Kpa)5
Air required for combustion 100% (m3/h)1770
Alternator fan air flow (m3/m)54
Motor fan air flow (m3/s)6.8
Open generator weight3200 Kg
Soundproofed generator weight4400 Kg

Open

  • H: 1750 mm
  • L: 3450 mm
  • W: 1300 mm

Closed

  • H: 2200 mm
  • L: 4500 mm
  • W: 1700 mm

JBJ XLP5 450-500 KVA

50 Hz - 1500 rpmVoltage: 380 / 220 V
Motor modelSCANIA
Cooling systemsRadiator
PRP generator power (kVA)/KWe450/360
STP generator power (kVA)/KWe500/400
Cos Phi power factor0.8
Number of cylinders6 in line
Speed (R.P.M.)1500
Fuel consumption (l/h)At 100%: 91.42 l/h
At 75%: 68.54 l/h
Open generator fuel tank300 l
Soundproofed generator fuel tank450 l
Max. exhaust gas temperature 100% (ºC)536
Exhaust gas flow 100% (m3/min)1975
Max. acceptable backpressure (Kpa)16
Air required for combustion 100% (m3/h)1600
Alternator fan air flow (m3/m)1.035
Motor fan air flow (m3/s)9.58
Open generator weight2917 Kg
Soundproofed generator weight5190 Kg

Open

  • H: 1750 mm
  • L: 3650 mm
  • W: 1250 mm

Closed

  • H: 2200 mm
  • L: 4500 mm
  • W: 1700 mm