JBJ SP5 50-55 KVA
50 Hz - 1500 rpm | Voltage: 380 / 220 V |
---|---|
Motor model | Iveco |
Cooling systems | Radiator |
PRP generator power (kVA)/KWe | 50/40 |
STP generator power (kVA)/KWe | 55/44 |
Cos Phi power factor | 0.8 |
Number of cylinders | 4 in line |
Speed (R.P.M.) | 1500 |
Fuel consumption (l/h) | At 100%: 11.9 l/h |
At 75%: 9.5 l/h | |
Open generator fuel tank | 100 l |
Soundproofed generator fuel tank | 150 l |
Max. exhaust gas temperature 100% (ºC) | 541 |
Exhaust gas flow 100% (m3/min) | 698 |
Max. acceptable backpressure (Kpa) | 5 |
Air required for combustion 100% (m3/h) | 675 |
Alternator fan air flow (m3/m) | 11.8 |
Motor fan air flow (m3/s) | 1.6 |
Open generator weight | 950 Kg |
Soundproofed generator weight | 1425 Kg |
Open
- H: 1450 mm
- L: 2150 mm
- W: 700 mm
Closed
- H: 1800 mm
- L: 2600 mm
- W: 1100 mm
JBJ SP5 100-110 KVA
50 Hz - 1500 rpm | Voltage: 380 / 220 V |
---|---|
Motor model | Iveco |
Cooling systems | Radiator |
PRP generator power (kVA)/KWe | 100/80 |
STP generator power (kVA)/KWe | 110/55 |
Cos Phi power factor | 0.8 |
Number of cylinders | 4 in line |
Speed (R.P.M.) | 1500 |
Fuel consumption (l/h) | At 100%: 22 l/h |
At 75%: 16.2 l/h | |
Open generator fuel tank | 100 l |
Soundproofed generator fuel tank | 200 l |
Max. exhaust gas temperature 100% (ºC) | 535 |
Exhaust gas flow 100% (m3/min) | 443 |
Max. acceptable backpressure (Kpa) | 5 |
Air required for combustion 100% (m3/h) | 617 |
Alternator fan air flow (m3/m) | 19.3 |
Motor fan air flow (m3/s) | 2.2 |
Open generator weight | 1250 Kg |
Soundproofed generator weight | 1950 Kg |
Open
H: 1600 mm
L: 2350 mm
W: 750 mm
Closed
- H: 1800 mm
- L: 2900 mm
- W: 1100 mm
JBJ MP5 125-138 KVA
50 Hz - 1500 rpm | Voltage: 380 / 220 V |
---|---|
Motor model | Iveco |
Cooling systems | Radiator |
PRP generator power (kVA)/KWe | 125/100 |
STP generator power (kVA)/KWe | 138/110.4 |
Cos Phi power factor | 0.8 |
Number of cylinders | 6 in line |
Speed (R.P.M.) | 1500 |
Fuel consumption (l/h) | At 100%: 28.8 l/h |
At 75%: 23.2 l/h | |
Open generator fuel tank | 200 l |
Soundproofed generator fuel tank | 350 l |
Max. exhaust gas temperature 100% (ºC) | 528 |
Exhaust gas flow 100% (m3/min) | 498 |
Max. acceptable backpressure (Kpa) | 5 |
Air required for combustion 100% (m3/h) | 475 |
Alternator fan air flow (m3/m) | 19.3 |
Motor fan air flow (m3/s) | 3.2 |
Open generator weight | 1425 Kg |
Soundproofed generator weight | 2275 Kg |
Open
- H: 1650 mm
- L: 2800 mm
- W: 800 mm
Closed
- H: 1950 mm
- L: 3400 mm
- W: 1350 mm
JBJ MP5 170-185 KVA
50 Hz - 1500 rpm | Voltage: 380 / 220 V |
---|---|
Motor model | Iveco |
Cooling systems | Radiator |
PRP generator power (kVA)/KWe | 170/136 |
STP generator power (kVA)/KWe | 185/148 |
Cos Phi power factor | 0.8 |
Number of cylinders | 6 in line |
Speed (R.P.M.) | 1500 |
Fuel consumption (l/h) | At 100%: 34.9 l/h |
At 75%: 26.2 l/h | |
Open generator fuel tank | 200 l |
Soundproofed generator fuel tank | 350 l |
Max. exhaust gas temperature 100% (ºC) | 570 |
Exhaust gas flow 100% (m3/min) | 1763.9 |
Max. acceptable backpressure (Kpa) | 5 |
Air required for combustion 100% (m3/h) | 586 |
Alternator fan air flow (m3/m) | 32 |
Motor fan air flow (m3/s) | 3.8 |
Open generator weight | 1500 Kg |
Soundproofed generator weight | 2350 Kg |
Open
- H: 1700 mm
- L: 2800 mm
- W: 800 mm
Closed
- H: 1950 mm
- L: 3400 mm
- W: 1350 mm
JBJ MP5 200-220 KVA
50 Hz - 1500 rpm | Voltage: 380 / 220 V |
---|---|
Motor model | Iveco |
Cooling systems | Radiator |
PRP generator power (kVA)/KWe | 200/160 |
STP generator power (kVA)/KWe | 220/176 |
Cos Phi power factor | 0.8 |
Number of cylinders | 6 in line |
Speed (R.P.M.) | 1500 |
Fuel consumption (l/h) | At 100%: 44 l/h |
At 75%: 35.7 l/h | |
Open generator fuel tank | 200 l |
Soundproofed generator fuel tank | 350 l |
Max. exhaust gas temperature 100% (ºC) | 550 |
Exhaust gas flow 100% (m3/min) | 786 |
Max. acceptable backpressure (Kpa) | 6 |
Air required for combustion 100% (m3/h) | 754 |
Alternator fan air flow (m3/m) | 32 |
Motor fan air flow (m3/s) | 3.8 |
Open generator weight | 1750 Kg |
Soundproofed generator weight | 2650 Kg |
Open
- H: 1700 mm
- L: 2750 mm
- W: 800 mm
Closed
- H: 2150 mm
- L: 3800 mm
- W: 1350 mm
JBJ MP5 300-330 KVA
50 Hz - 1500 rpm | Voltage: 380 / 220 V |
---|---|
Motor model | Doosan |
Cooling systems | Radiator |
PRP generator power (kVA)/KWe | 300/240 |
STP generator power (kVA)/KWe | 330/264 |
Cos Phi power factor | 0.8 |
Number of cylinders | 6 in line |
Speed (R.P.M.) | 1500 |
Fuel consumption (l/h) | At 100%: 63 l/h |
At 75%: 47 l/h | |
Open generator fuel tank | 300 l |
Soundproofed generator fuel tank | 350 l |
Max. exhaust gas temperature 100% (ºC) | 590 |
Exhaust gas flow 100% (m3/min) | 1442 |
Max. acceptable backpressure (Kpa) | 6 |
Air required for combustion 100% (m3/h) | 1298 |
Alternator fan air flow (m3/m) | 32 |
Motor fan air flow (m3/s) | 5.67 |
Open generator weight | 2560 Kg |
Soundproofed generator weight | 3510 Kg |
Open
- H: 1700 mm
- L: 3300 mm
- W: 1150 mm
Closed
- H: 2200 mm
- L: 4500 mm
- W: 1700 mm
JBJ MP5 350-385 KVA
50 Hz - 1500 rpm | Voltage: 380 / 220 V |
---|---|
Motor model | Iveco |
Cooling systems | Radiator |
PRP generator power (kVA)/KWe | 350/280 |
STP generator power (kVA)/KWe | 385/308 |
Cos Phi power factor | 0.8 |
Number of cylinders | 6 in line |
Speed (R.P.M.) | 1500 |
Fuel consumption (l/h) | At 100%: 70 l/h |
At 75%: 57.3 l/h | |
Open generator fuel tank | 300 l |
Soundproofed generator fuel tank | 350 l |
Max. exhaust gas temperature 100% (ºC) | 479 |
Exhaust gas flow 100% (m3/min) | 1549 |
Max. acceptable backpressure (Kpa) | 5 |
Air required for combustion 100% (m3/h) | 1.495 |
Alternator fan air flow (m3/m) | 32 |
Motor fan air flow (m3/s) | 6.8 |
Open generator weight | 3100 Kg |
Soundproofed generator weight | 4300 Kg |
Open
- H: 1750 mm
- L: 3450 mm
- W: 1300 mm
Closed
- H: 2200 mm
- L: 4500 mm
- W: 1700 mm
JBJ MP5 400-440 KVA
50 Hz - 1500 rpm | Voltage: 380 / 220 V |
---|---|
Motor model | Iveco |
Cooling systems | Radiator |
PRP generator power (kVA)/KWe | 400/320 |
STP generator power (kVA)/KWe | 440/352 |
Cos Phi power factor | 0.8 |
Number of cylinders | 6 in line |
Speed (R.P.M.) | 1500 |
Fuel consumption (l/h) | At 100%: 87.5 l/h |
At 75%: 72.5 l/h | |
Open generator fuel tank | 300 l |
Soundproofed generator fuel tank | 350 l |
Max. exhaust gas temperature 100% (ºC) | 445 |
Exhaust gas flow 100% (m3/min) | 1836 |
Max. acceptable backpressure (Kpa) | 5 |
Air required for combustion 100% (m3/h) | 1770 |
Alternator fan air flow (m3/m) | 54 |
Motor fan air flow (m3/s) | 6.8 |
Open generator weight | 3200 Kg |
Soundproofed generator weight | 4400 Kg |
Open
- H: 1750 mm
- L: 3450 mm
- W: 1300 mm
Closed
- H: 2200 mm
- L: 4500 mm
- W: 1700 mm
JBJ XLP5 450-500 KVA
50 Hz - 1500 rpm | Voltage: 380 / 220 V |
---|---|
Motor model | SCANIA |
Cooling systems | Radiator |
PRP generator power (kVA)/KWe | 450/360 |
STP generator power (kVA)/KWe | 500/400 |
Cos Phi power factor | 0.8 |
Number of cylinders | 6 in line |
Speed (R.P.M.) | 1500 |
Fuel consumption (l/h) | At 100%: 91.42 l/h |
At 75%: 68.54 l/h | |
Open generator fuel tank | 300 l |
Soundproofed generator fuel tank | 450 l |
Max. exhaust gas temperature 100% (ºC) | 536 |
Exhaust gas flow 100% (m3/min) | 1975 |
Max. acceptable backpressure (Kpa) | 16 |
Air required for combustion 100% (m3/h) | 1600 |
Alternator fan air flow (m3/m) | 1.035 |
Motor fan air flow (m3/s) | 9.58 |
Open generator weight | 2917 Kg |
Soundproofed generator weight | 5190 Kg |
Open
- H: 1750 mm
- L: 3650 mm
- W: 1250 mm
Closed
- H: 2200 mm
- L: 4500 mm
- W: 1700 mm